FL4595 – Tri County Metals

Florida product approval FL4595-R8 for Roofing Products – Non-structural Metal RF, as listed in ProdApproval’s data as of Sep 29, 2026.

FL#
FL4595-R8
Manufacturer
Tri County Metals
Code version
2020 Florida Building Code
Status in our data
Approved
Products
20

Official record on floridabuilding.org →Use on a spec sheet →

Verify approval status on floridabuilding.org before submitting.

Approved products under FL4595-R8

Approval #ModelDescriptionDesign pressureWind-borne debrisHVHZOutside HVHZ
FL4595.15V CrimpMin. 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood+N/A/-101.0PSFN/ANoYes
FL4595.25V CrimpMin. 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32" Plywood+N/A/-101.0PSFN/ANoYes
FL4595.3Aluminum Mechanical-Seam Lok.032" Aluminum Mechanical Lock 16" Wide Roof Panel over Plywood+N/A/-93.5 psfN/AYesYes
FL4595.4Aluminum Mechanical-Seam Lok 2".032" Aluminum, 2" Mechanical Lock, 19" Wide Roof Panel over 22 Ga. Steel Deck+N/A/-138.5psfN/AYesYes
FL4595.5Aluminum TCM Lok0.032" Aluminum TCM Lok Roof Panel over 7/16" OSB or 15/32" Plywood+N/A/-112.5psfN/ANoYes
FL4595.6Mechanical-Seam Lok 1-½"1-½" Mechanical Lock, 24 Ga., 16" Wide Roof Panel over Plywood+N/A/-123.5psfN/AYesYes
FL4595.7Mechanical-Seam Lok 2"2" Mechanical Lock, 24 Ga. Steel, 18-7/8" Wide Roof Panel over 22 Ga. Steel Deck+N/A/-153.5psfN/AYesYes
FL4595.8Nail Strip 1"1" Nailstrip, 24 Ga. Steel 16" Wide Roof Panel over 15/32" Plywood+N/A/-153.5psfN/ANoYes
FL4595.9Nail Strip 1-½"1-½" Nail Strip, 24 Ga. 15-½" Wide Roof Panel over Plywood+N/A/-116.0psfN/AYesYes
FL4595.10PBRMin. 26 Ga. PBR Roof Panel over 15/32" Plywood+N/A/-93.5 PSFN/ANoYes
FL4595.11PBRMin. 26 Ga. PBR Roof Panel over 1x4 Wood Purlins over 15/32" Plywood+N/A/-78.5 PSFN/ANoYes
FL4595.12Snap-Lok 1-½"1-½" Snap Lok, 24 Ga. , 16" Wide Roof Panel over Plywood+N/A/-116.0psfN/AYesYes
FL4595.13Snap-Lok 1-¾"1-¾" Snap Lock, 24 Ga. Steel, 17-¾" Wide Roof Panel over 22 Ga. Steel Decking+N/A/-108.5psfN/AYesYes
FL4595.14TCM-LokMin. 24 Ga. TCM-Lok Roof Panel over 15/32" Plywood+N/A/-116.0PSFN/ANoYes
FL4595.15Ultra-RibMin. 29 Ga. Ultra-Rib Roof Panel over 15/32" Plywood+N/A/-146.0PSFN/ANoYes
FL4595.16Ultra-RibMin. 29 Ga. Ultra Rib, 36" wide, Roof Panel over 1x4 Wood Purlins over 15/32" Plywood+N/A/-138.5PSFN/ANoYes
FL4595.17Ultra-RibMin. 29 Ga. Ultra Rib, 36" wide, Roof Panel over 1x4 Wood Purlins over 15/32" Plywood+N/A/-86.0PSFN/ANoYes
FL4595.18Ultra-RibMin. 29 Ga. Ultra-Rib Roof Panel over 7/16" OSB+N/A/-123.5PSFN/ANoYes
FL4595.19Ultra-Rib29 Ga. Ultra-Rib Roof Panel over 15/32" Plywood+N/A/-101.0PSFN/ANoYes
FL4595.20Ultra-Rib29 Ga. Ultra-Rib Roof Panel over 1x4 Wood Purlins over 15/32" Plywood+N/A/-131.0PSFN/ANoYes

Fill a spec sheet with FL4595

On the contractor form, go to the Roofing Products – Non-structural Metal RF row and type 4595 in the Florida Product Approval # box to fill the row. Walton County users can print a PDF that follows the county’s sheet; see the Walton County Product Approval Specification Sheet guide.