FL42382 – Cornerstone Building Brands (MBCI, ABC, UCC, and Reeds)

Florida product approval FL42382-R1 for Structural Components – Deck-Roof, as listed in ProdApproval’s data as of Sep 29, 2026.

FL#
FL42382-R1
Manufacturer
Cornerstone Building Brands (MBCI, ABC, UCC, and Reeds)
Code version
2023 Florida Building Code
Status in our data
Approved
Products
17

Official record on floridabuilding.org →Use on a spec sheet →

Verify approval status on floridabuilding.org before submitting.

Approved products under FL42382-R1

Approval #ModelDescriptionDesign pressureWind-borne debrisHVHZOutside HVHZ
FL42382.101: Steel DoubleLok on purlins24ga (min) DoubleLok on 16ga (min) purlins+N/A/-220N/ANoYes
FL42382.202: Steel Mech Seam purlins26ga or 24ga (min) Mech Seam on 16ga (min) purlins+N/A/-135.3N/ANoYes
FL42382.303: Steel ML200 on purlins24ga (min) ML200 on 16ga (min) purlins+N/A/-120N/ANoYes
FL42382.404: Steel SuperLok on purlins24ga or 22ga (min) SuperLok on 16ga (min) purlins+N/A/-130N/ANoYes
FL42382.505: Steel Secure Seam on purlins26ga (min) Secure Seam on 16ga (min) purlins+N/A/-88.4N/ANoYes
FL42382.606: Steel LokSeam on purlins24ga (min) LokSeam on 16ga (min) purlins+N/A/-40N/ANoYes
FL42382.707: Steel Rib panel on purlins29ga or 26ga (min) Rib panel on 18ga or 16ga (min) purlins+N/A/-47.2N/ANoYes
FL42382.808: Steel Rib panel on wood purlins29ga (min) Rib panel on 1x4 (min) wood purlins+N/A/-138.9N/ANoYes
FL42382.909: Steel 5V on wood purlins29ga (min) 5V panel on 1x4 (min) wood purlins+N/A/-70.25N/ANoYes
FL42382.1010: Steel Corrugated on purlins26ga or 24ga (min) corrugated panel with nominal 7/8" rib height on 16ga (min) purlins+N/A/-140N/ANoYes
FL42382.1111: Steel 7.2 Panel on purlins26ga (min) 7.2 Panel on 16ga (min) purlins+N/A/-52.5N/ANoYes
FL42382.1212: Steel PBR on purlins22ga-29ga PBR on 16ga (min) purlins+96/-163N/ANoYes
FL42382.1313: Steel PBU/M-Panel on purlins26ga (min) PBR/M-Panel on 16ga (min) purlins+N/A/-52.5N/ANoYes
FL42382.1414: Steel UltraDek on purlins24ga (min) UltraDek on 16ga (min) purlins+N/A/-50N/ANoYes
FL42382.1515: Steel TS 324 on purlins24ga or 22ga (min) TS 324 on 16ga (min) purlins+N/A/-183.3N/ANoYes
FL42382.1616: Steel BattenLok HS on purlins24ga (min) BattenLok HS on 16ga (min) purlins+N/A/-71.2N/ANoYes
FL42382.1717: Steel Retro-R on purlins26ga (min) Retro-R on 16ga (min) purlins+N/A/-130.5N/ANoYes

Fill a spec sheet with FL42382

On the contractor form, go to the Structural Components – Deck-Roof row and type 42382 in the Florida Product Approval # box to fill the row. Walton County users can print a PDF that follows the county’s sheet; see the Walton County Product Approval Specification Sheet guide.