FL37354 – Master Wall Inc.®
Florida product approval FL37354-R2 for Panel Wall – EIFS, as listed in ProdApproval’s data as of Sep 29, 2026.
- FL#
- FL37354-R2
- Manufacturer
- Master Wall Inc.®
- Code version
- 2023 Florida Building Code
- Status in our data
- Approved
- Products
- 17
Official record on floridabuilding.org →Use on a spec sheet →
Verify approval status on floridabuilding.org before submitting.
Approved products under FL37354-R2
| Approval # | Model | Description | Design pressure | Wind-borne debris | HVHZ | Outside HVHZ |
|---|---|---|---|---|---|---|
| FL37354.1 | Aggre-flex Drainage EIFS Assembly EIFSWPM01 | Drainage EIFS, Mechanically Attached, wood frame over plywood substrate | +60/-25 | N/A | No | Yes |
| FL37354.2 | Aggre-flex Drainage EIFS Assembly EIFSWPM02 | Drainage EIFS, Mechanically Attached, wood frame with plywood sheathing | +60/-35 | N/A | No | Yes |
| FL37354.3 | Aggre-flex EIFS Assembly EIFSMGA01 | EIFS, Adhesively Attached, metal frame with gypsum substrate | +90/-50 | N/A | No | Yes |
| FL37354.4 | Aggre-flex EIFS Assembly EIFSMGA02 | EIFS, Adhesively Attached, metal frame with gypsum substrate | +95/-75 | N/A | No | Yes |
| FL37354.5 | Aggre-flex EIFS Assembly EIFSMGA03 | EIFS, Adhesively Attached, metal frame with gypsum substrate | +90/-60 | N/A | No | Yes |
| FL37354.6 | Aggre-flex EIFS Assembly EIFSMGA04 | EIFS, Adhesively Attached, metal frame with Dens Glass Gold® substrate | +65/-45 | N/A | No | Yes |
| FL37354.7 | Aggre-flex EIFS Assembly EIFSWGA01 | EIFS, Adhesively Attached, wood frame with gypsum substrate | +55/-45 | N/A | No | Yes |
| FL37354.8 | Aggre-flex EIFS Assembly EIFSWPM01 | EIFS, Mechanically Attached, wood frame plywood substrate | +60/-25 | N/A | No | Yes |
| FL37354.9 | Aggre-flex EIFS Assembly EIFSWPM02 | EIFS, Mechanically Attached, wood frame with plywood substrate | +60/-35 | N/A | No | Yes |
| FL37354.10 | QRW1 Drainage EIFS Assembly QEIFSWPM01 | Drainage EIFS, Mechanically Attached, wood frame with OSB substrate | +55/-30 | N/A | No | Yes |
| FL37354.11 | Rollershield Drainage CIFS® Assembly EIFSMGA01 | Drainage EIFS, Adhesively Attached, metal frame with gypsum sheathing | +90/-50 | N/A | No | Yes |
| FL37354.12 | Rollershield Drainage CIFS® Assembly EIFSMGA02 | Drainage EIFS, Adhesively Attached, metal frame with gypsum substrate | +95/-75 | N/A | No | Yes |
| FL37354.13 | Rollershield Drainage CIFS® Assembly EIFSMGA03 | Drainage EIFS, Adhesively Attached, metal frame with gypsum sheathing | +90/-60 | N/A | No | Yes |
| FL37354.14 | Rollershield Drainage CIFS® Assembly EIFSMGA04 | Drainage EIFS, Adhesively Atttached, metal frame with Dens Glass Gold® sheathing | +65/-45 | N/A | No | Yes |
| FL37354.15 | Rollershield Drainage CIFS® Assembly EIFSWGA01 | Drainage EIFS, Adhesively Attached, wood frame with gypsum sheathing | +55/-45 | N/A | No | Yes |
| FL37354.16 | Rollershield Drainage CIFS® Assembly EIFSWPA01 | Drainage EIFS, Adhesively Attached, wood frame with plywood sheathing | +65/-60 | N/A | No | Yes |
| FL37354.17 | Rollershield Drainage CIFS® Assembly EIFSWPA02 | Drainage EIFS, Adhesively Attached, wood frame OSB substrate | +55/-55 | N/A | No | Yes |
Fill a spec sheet with FL37354