FL32994 – Petersen Aluminum Corp.

Florida product approval FL32994-R5 for Roofing Products – Non-structural Metal RF, as listed in ProdApproval’s data as of Sep 29, 2026.

FL#
FL32994-R5
Manufacturer
Petersen Aluminum Corp.
Code version
2023 Florida Building Code
Status in our data
Approved
Products
21

Official record on floridabuilding.org →Use on a spec sheet →

Verify approval status on floridabuilding.org before submitting.

Approved products under FL32994-R5

Approval #ModelDescriptionDesign pressureWind-borne debrisHVHZOutside HVHZ
FL32994.132994.01 PAC-150 x 90° Seam (S1).032" (min.) x 12" thru 20" Wide Aluminum Panel over Wood Deck+N/A/-99.3N/ANoYes
FL32994.232994.02 PAC-150 x 180° Seam (S2).032" (min.) x 12" thru 20" Wide Aluminum Panel over Wood Deck+N/A/-166.8N/ANoYes
FL32994.332994.03 PAC-150 x 90° Seam (S1)24 ga. (min.) x 12" thru 20" Wide Steel Panel over Wood Deck+N/A/-114.3N/ANoYes
FL32994.432994.04 PAC-150 x 180° Seam (S2)24 ga. (min.) x 12" thru 20" Wide Steel Panel over Wood Deck+N/A/-136.8N/ANoYes
FL32994.532994.05 SNAP-CLAD (S1).032" (min.) x 12" thru 18" Wide Aluminum Panel over Wood Deck+N/A/-153.5N/ANoYes
FL32994.632994.06 SNAP-CLAD (S2).040" (min.) x 12" thru 18" Wide Aluminum Panel over Wood Deck+N/A/-174.2N/ANoYes
FL32994.732994.07 SNAP-CLAD (S3)24 ga. (min.) x 12" thru 18" Wide Steel Panel over Wood Deck+N/A/-144.5N/ANoYes
FL32994.832994.08 Tite-Loc Plus (S1).032" (min.) x 12" thru 18" Wide Aluminum Panel over Wood Deck+N/A/-174.2N/ANoYes
FL32994.932994.09 Tite-Loc Plus (S2)24 ga. (min.) x 12" thru 18" Wide Steel Panel over Wood Deck+N/A/-204.5N/ANoYes
FL32994.1032994.10 PAC T-250 (S1)16" Wide x .032" (min) Aluminum Panel w/Continuous Clips+N/A/-140.40N/ANoYes
FL32994.1132994.11 PAC T-250 (S2)16" Wide x .032" (min) Aluminum Panel w/Individual Clips+N/A/-65.00N/ANoYes
FL32994.1232994.12 PAC T-250 (S3)16" Wide x .040" (min) Aluminum Panel w/Continuous Clips+N/A/-127.15N/ANoYes
FL32994.1332994.13 PAC T-250 (S4)16" Wide x .040" (min) Aluminum Panel w/Individual Clips+N/A/-78.00N/ANoYes
FL32994.1432994.14 PAC T-250 (S5)16" Wide x 24 Ga. (min) Steel Panel w/Continuous Clips+N/A/-119.85N/ANoYes
FL32994.1532994.15 PAC T-250 (S6)16" Wide x 24 Ga. (min) Steel Panel w/Individual Clips+N/A/-65.00N/ANoYes
FL32994.1632994.16 PAC T-250 (S7)16" Wide x 22 Ga. (min) Steel Panel w/Continuous Clips+N/A/-147.95N/ANoYes
FL32994.1732994.17 PAC T-250 (S8)16" Wide x 22 Ga. (min) Steel Panel w/Individual Clips+N/A/-72.80N/ANoYes
FL32994.187.2 Panel (S1) 2' - 5' Spans36" Wide x 24 Ga. (min.) Steel+N/A/-159.70N/ANoYes
FL32994.197.2 Panel (S2) 2' - 5' Spans36" Wide x .032" (min.) Aluminum+N/A/-104.05N/ANoYes
FL32994.207.2 Panel (S3) 1' - 5' Spans36" Wide x .050" (min.) Aluminum+N/A/-192.10N/ANoYes
FL32994.217.2 Panel (S4) 7 - 10' Spans36" Wide x .050" (min.) Aluminum+N/A/-57.20N/ANoYes

Fill a spec sheet with FL32994