FL31335 – Marvin

Florida product approval FL31335-R4 for Windows – Casement, as listed in ProdApproval’s data as of Sep 29, 2026.

FL#
FL31335-R4
Manufacturer
Marvin
Code version
2023 Florida Building Code
Status in our data
Approved
Products
22

Official record on floridabuilding.org →Use on a spec sheet →

Verify approval status on floridabuilding.org before submitting.

Approved products under FL31335-R4

Approval #ModelDescriptionDesign pressureWind-borne debrisHVHZOutside HVHZ
FL31335.1UCANF 36102 and UCA 36102Ultimate Casement Narrow Frame and Ultimate Casement 407-H-918+40/-40NoNoYes
FL31335.2UCANF 3697 and UCA 3697Ultimate Casement Narrow Frame and Ultimate Casement 407-H-918+50/-50NoNoYes
FL31335.3UCANF 4092 and UCA 4092Ultimate Casement Narrow Frame and Ultimate Casement 407-H-918+50/-50NoNoYes
FL31335.4UCANF 40x96-1/8 and UCA 40x96-1/8Ultimate Casement Narrow Frame and Ultimate Casement 407-H-918+40/-40NoNoYes
FL31335.5UCANF 44x71-1/8 and UCA 44x71-1/8Ultimate Casement Narrow Frame and Ultimate Casement 407-H-918+50/-50NoNoYes
FL31335.6UCANF 44x91-1/8 and UCA 44x91-1/8Ultimate Casement Narrow Frame and Ultimate Casement 407-H-918+40/-40NoNoYes
FL31335.7UCANFP 60X99 and UCAP 60x99Ultimate Casement Narrow Frame Picture and Ultimate Casement Picture 407-H-1016+50/-50NoNoYes
FL31335.8UCANFP 64104 and UCAP 64104 and UCANFPOP 64104 and UCAPOP 64104Ultimate Casement Narrow Frame Picture and Ultimate Casement Picture and Ultimate Casement Narrow Frame Push Out Picture and Ultimate Casement Push Out Picture 407-H-917+50/-50NoNoYes
FL31335.9UCANFPO 3672 and UCAPO 3672Ultimate Casement Narrow Frame Push Out and Ultimate Casement Push Out 407-H-992+50/-50NoNoYes
FL31335.10UCANFPO 3697 and UCAPO 3697Ultimate Casement Narrow Frame Push Out and Ultimate Casement Push Out 407-H-992+35/-35NoNoYes
FL31335.11UCANFPO 4092 and UCAPO 4092Ultimate Casement Narrow Frame Push Out and Ultimate Casement Push Out 407-H-992+35/-35NoNoYes
FL31335.12UCANFRT 3696 and UCART 3696Ultimate Casement Narrow Frame Round Top and Ultimate Casement Round Top 407-H-916+50/-50NoNoYes
FL31335.13UCANFRT 4092 and UCART 4092Ultimate Casement Narrow Frame Round Top and Ultimate Casement Round Top 407-H-916+50/-50NoNoYes
FL31335.14UCANFSTATPOLY 64X96-1/8 and UCASTATPOLY 64X96-1/8Ultimate Casement Narrow Frame Stationary Polygon and Ultimate Casement Stationary Polygon 407-H-1116+50/-50NoNoYes
FL31335.15UCANFSTATRT 64x96-1/8 and UCASTATRT 64x96-1/8Ultimate Casement Narrow Frame Stationary Round Top and Ultimate Casement Stationary Round Top 407-H-1116+50/-50NoNoYes
FL31335.16UCAPOP 7272 and UCAP 7272Ultimate Casement Push Out Picture and Ultimate Casement Picture 407-H-917+50/-50NoNoYes
FL31335.17UCAPOP 80120 and UCAP 80120Ultimate Casement Push Out Picture and Ultimate Casement Picture 407-H-917+40/-40NoNoYes
FL31335.18UCAPOP 8897 and UCAP 8897Ultimate Casement Push Out Picture and Ultimate Casement Picture 407-H-917+50/-50NoNoYes
FL31335.19UCART 4072Ultimate Casement Round Top 407-H-1006+50/-50NoNoYes
FL31335.20UCASTATPOLY 72X71-1/4Ultimate Casement Stationary Polygon 407-H-1062+50/-50NoNoYes
FL31335.21UCASTATPOLY 88 X 96-1/8Ultimate Casement Stationary Polygon 407-H-1062+50/-50NoNoYes
FL31335.22UCASTATRT 88x96-1/8Ultimate Casement Stationary Round Top 407-H-1011+50/-50NoNoYes

Fill a spec sheet with FL31335

On the contractor form, go to the Windows – Casement row and type 31335 in the Florida Product Approval # box to fill the row. Walton County users can print a PDF that follows the county’s sheet; see the Walton County Product Approval Specification Sheet guide.