FL31273 – Marvin
Florida product approval FL31273-R2 for Windows – Casement, as listed in ProdApproval’s data as of Sep 29, 2026.
- FL#
- FL31273-R2
- Manufacturer
- Marvin
- Code version
- 2023 Florida Building Code
- Status in our data
- Approved
- Products
- 17
Official record on floridabuilding.org →Use on a spec sheet →
Verify approval status on floridabuilding.org before submitting.
Approved products under FL31273-R2
| Approval # | Model | Description | Design pressure | Wind-borne debris | HVHZ | Outside HVHZ |
|---|---|---|---|---|---|---|
| FL31273.1 | UWCA 3697 | Ultimate Wood Casement 407-H-1067 | +50/-50 | No | No | Yes |
| FL31273.2 | UWCA 4072 | Ultimate Wood Casement 407-H-1067 | +50/-50 | No | No | Yes |
| FL31273.3 | UWCA 4092 | Ultimate Wood Casement 407-H-1067 | +50/-50 | No | No | Yes |
| FL31273.4 | UWCA PO 3672 | Ultimate Wood Casement Push Out 407-H-1067 | +50/-50 | No | No | Yes |
| FL31273.5 | UWCA PO 3697 | Ultimate Wood Casement Push Out 407-H-1067 | +35/-35 | No | No | Yes |
| FL31273.6 | UWCA PO 4092 | Ultimate Wood Casement Push Out 407-H-1067 | +35/-35 | No | No | Yes |
| FL31273.7 | UWCA RT 3697 | Ultimate Wood Casement Round Top 407-H-1116 | +50/-50 | No | No | Yes |
| FL31273.8 | UWCA RT 4072 | Ultimate Wood Casement Round Top 407-H-1006 | +50/-50 | No | No | Yes |
| FL31273.9 | UWCA RT 4092 | Ultimate Wood Casement Round Top 407-H-1116 | +50/-50 | No | No | Yes |
| FL31273.10 | UWCA RT ST 6497 | Ultimate Wood Casement Round Top Stationary 407-H-1116 | +50/-50 | No | No | Yes |
| FL31273.11 | UWCA ST POLY 6497 | Ultimate Wood Casement Stationary Poly 407-H-1116 | +50/-50 | No | No | Yes |
| FL31273.12 | UWCA ST POLY 7272 | Ultimate Wood Casement Stationary Polygon 407-H-1062 | +50/-50 | No | No | Yes |
| FL31273.13 | UWCA ST POLY 8897 | Ultimate Wood Casement Stationary Polygon 407-H-1062 | +50/-50 | No | No | Yes |
| FL31273.14 | UWCAP 6497 | Ultimate Wood Casement Picture 407-H-1066 | +50/-50 | No | No | Yes |
| FL31273.15 | UWCAP 7272 | Ultimate Wood Casement Picture 407-H-1006 | +50/-50 | No | No | Yes |
| FL31273.16 | UWCAP 8897 | Ultimate Wood Casement Picture 407-H-1006 | +50/-50 | No | No | Yes |
| FL31273.17 | UWCAP RT 8897 | Ultimate Wood Casement Picture Round Top 407-H-1006 | +50/-50 | No | No | Yes |
Fill a spec sheet with FL31273
On the contractor form, go to the Windows – Casement row and type 31273 in the Florida Product Approval # box to fill the row. Walton County users can print a PDF that follows the county’s sheet; see the Walton County Product Approval Specification Sheet guide.