FL24508 – Reed Metal, Inc.

Florida product approval FL24508-R3 for Roofing Products – Non-structural Metal RF, as listed in ProdApproval’s data as of Sep 29, 2026.

FL#
FL24508-R3
Manufacturer
Reed Metal, Inc.
Code version
2020 Florida Building Code
Status in our data
Approved
Products
18

Official record on floridabuilding.org →Use on a spec sheet →

Verify approval status on floridabuilding.org before submitting.

Approved products under FL24508-R3

Approval #ModelDescriptionDesign pressureWind-borne debrisHVHZOutside HVHZ
FL24508.124 Ga. Secure-Seam (Purlins) - Anchor Pattern ANon-structural standing seam min. 24 ga. metal roof panels installed over 1x4 purlins over nominal 15/32" plywood sheathing roof deck, w/ or w/o asphalt shingles & 30# felt paper between the purlins & the roof deck, for use in re-roofing.+N/A/-78.5N/ANoYes
FL24508.224 Ga. Secure-Seam (Purlins) - Anchor Pattern BNon-structural standing seam min. 24 ga. metal roof panels installed over 1x4 purlins over nominal 15/32" plywood sheathing roof deck, w/ or w/o asphalt shingles & 30# felt paper between the purlins & the roof deck, for use in re-roofing.+N/A/-101.0N/ANoYes
FL24508.324 Ga. Secure-Seam - Anchor Pattern ANon-structural standing seam minimum 24 gauge metal roof panels installed over nominal 15/32" plywood sheathing roof deck for use in new construction and re-roofing applications.+N/A/-63.5N/ANoYes
FL24508.424 Ga. Secure-Seam - Anchor Pattern BNon-structural standing seam minimum 24 gauge metal roof panels installed over nominal 15/32" plywood sheathing roof deck for use in new construction and re-roofing applications.+N/A/-101.0N/ANoYes
FL24508.526 Ga. PBR Panel (Purlins) - Anchor Pattern ANon-structural through fastened min. 26 ga. metal roof panels installed over 1x4 purlins over nominal 15/32" plywood roof deck w/ or w/o asphalt shingles & 30# felt paper between the purlins & the roof deck, for use in re-roofing.+N/A/-56.0N/ANoYes
FL24508.626 Ga. PBR Panel (Purlins) - Anchor Pattern BNon-structural through fastened min. 26 ga. metal roof panels installed over 1x4 purlins over nominal 15/32" plywood roof deck w/ or w/o asphalt shingles & 30# felt paper between the purlins & the roof deck, for use in re-roofing.+N/A/-123.5N/ANoYes
FL24508.726 Ga. PBR Panel - Anchor Pattern ANon-structural through fastened minimum 26 gauge metal roof panels installed over nominal 15/32" plywood sheathing roof deck for use in new construction and re-roofing applications.+N/A/-56.0N/ANoYes
FL24508.826 Ga. PBR Panel - Anchor Pattern BNon-structural through fastened minimum 26 gauge metal roof panels installed over nominal 15/32" plywood sheathing roof deck for use in new construction and re-roofing applications.+N/A/-146.0N/ANoYes
FL24508.926 Ga. Residential Panel (Purlins) - Anchor Pattern ANon-structural through fastened min. 26 ga. metal roof panels installed over 1x4 purlins over over nominal 15/32" plywood sheathing roof deck w/ or w/o asphalt shingles & 30# felt paper between the purlins & the roof deck, for use in re-roofing.+N/A/-63.5N/ANoYes
FL24508.1026 Ga. Residential Panel (Purlins) - Anchor Pattern BNon-structural through fastened min. 26 ga. metal roof panels installed over 1x4 purlins over over nominal 15/32" plywood sheathing roof deck w/ or w/o asphalt shingles & 30# felt paper between the purlins & the roof deck, for use in re-roofing.+N/A/-123.5N/ANoYes
FL24508.1126 Ga. Residential Panel - Anchor Pattern ANon-structural through-fastened minimum 26 gauge metal roof panels installed over nominal 15/32" plywood sheathing roof deck for use in new construction and re-roofing applications.+N/A/-86.0N/ANoYes
FL24508.1226 Ga. Residential Panel - Anchor Pattern BNon-structural through-fastened minimum 26 gauge metal roof panels installed over nominal 15/32" plywood sheathing roof deck for use in new construction and re-roofing applications.+N/A/-168.5N/ANoYes
FL24508.1326 Ga. Secure-Seam - Anchor Pattern ANon-structural standing seam minimum 26 gauge metal roof panels installed over nominal 15/32" plywood sheathing roof deck for use in new construction and re-roofing applications.+N/A/-56.0N/ANoYes
FL24508.1426 Ga. Secure-Seam - Anchor Pattern BNon-structural standing seam minimum 26 gauge metal roof panels installed over nominal 15/32" plywood sheathing roof deck for use in new construction and re-roofing applications.+N/A/-86.0N/ANoYes
FL24508.1529 Ga. Residential Panel (Purlins) - Anchor Pattern ANon-structural through fastened min. 29 ga. metal roof panels installed over 1x4 purlins over nominal 7/16" OSB sheathing roof deck, w/ or w/o asphalt shingles & 30# felt paper between the purlins & the roof deck, for use in re-roofing.+N/A/-86.0N/ANoYes
FL24508.1629 Ga. Residential Panel (Purlins) - Anchor Pattern BNon-structural through fastened min. 29 ga. metal roof panels installed over 1x4 purlins over nominal 7/16" OSB sheathing roof deck, w/ or w/o asphalt shingles & 30# felt paper between the purlins & the roof deck, for use in re-roofing.+N/A/-176.0N/ANoYes
FL24508.1729 Ga. Residential Panel - Anchor Pattern ANon-structural through fastened minimum 29 gauge metal roof panels installed over nominal 7/16" OSB sheathing roof deck for use in new construction and re-roofing applications.+N/A/-20.8N/ANoYes
FL24508.1829 Ga. Residential Panel - Anchor Pattern BNon-structural through fastened minimum 29 gauge metal roof panels installed over nominal 7/16" OSB sheathing roof deck for use in new construction and re-roofing applications.+N/A/-108.5N/ANoYes

Fill a spec sheet with FL24508

On the contractor form, go to the Roofing Products – Non-structural Metal RF row and type 24508 in the Florida Product Approval # box to fill the row. Walton County users can print a PDF that follows the county’s sheet; see the Walton County Product Approval Specification Sheet guide.