FL24423 – Petersen Aluminum Corp.
Florida product approval FL24423-R5 for Roofing Products – Non-structural Metal RF, as listed in ProdApproval’s data as of Sep 29, 2026.
- FL#
- FL24423-R5
- Manufacturer
- Petersen Aluminum Corp.
- Code version
- 2023 Florida Building Code
- Status in our data
- Approved
- Products
- 14
Official record on floridabuilding.org →Use on a spec sheet →
Verify approval status on floridabuilding.org before submitting.
Approved products under FL24423-R5
| Approval # | Model | Description | Design pressure | Wind-borne debris | HVHZ | Outside HVHZ |
|---|---|---|---|---|---|---|
| FL24423.1 | 5-V-Crimp (.032" min.) | .032" (min.) Aluminum over 1/2" (min.) Plywood | +N/A/-176 | N/A | Yes | Yes |
| FL24423.2 | 5-V-Crimp (24 ga. min.) | 24 Ga. (min.) Steel over 1/2" (min.) Plywood | +N/A/-176 | N/A | Yes | Yes |
| FL24423.3 | Edge-Loc 1.0 (24 ga. min.) | 24 Ga. Steel over 1/2" (min.) Plywood | +N/A/-101 | N/A | Yes | Yes |
| FL24423.4 | PAC-150 (.032" min.) | .032" (min.) x 12" thru 20" Wide Aluminum Panel over Plywood Deck | +N/A/-166.75 | N/A | Yes | Yes |
| FL24423.5 | PAC-150 (24 ga. min.) | 24 Ga. (min.) x 12" thru 20" Wide Steel Panel over Plywood Deck | +N/A/-136.75 | N/A | Yes | Yes |
| FL24423.6 | SNAP-CLAD (.032" min.) | .032" (min.) x 12" thru 18" Wide Aluminum Panel over Steel Deck | +N/A/-174.25 | N/A | Yes | Yes |
| FL24423.7 | SNAP-CLAD (.032" min.) | .032" (min.) x 12" thru 18" Wide Aluminum Panel over Plywood Deck | +N/A/-153.50 | N/A | Yes | Yes |
| FL24423.8 | SNAP-CLAD (.040" min.) | .040" (min.) x 12" thru 18" Wide Aluminum Panel over Plywood Deck | +N/A/-174.25 | N/A | Yes | Yes |
| FL24423.9 | SNAP-CLAD (24 ga. min.) | 24 ga. (min.) x 12" thru 18" Wide Steel Panel over Plywood Deck | +N/A/-144.25 | N/A | Yes | Yes |
| FL24423.10 | SNAP-CLAD (24 ga. min.) | 24 ga. (min.) x 12" thru 18" Wide Steel Panel over Steel Deck | +N/A/-181.75 | N/A | Yes | Yes |
| FL24423.11 | Tite-Loc Plus (.032" min.) | .032" (min.) x 12" thru 18" Wide Aluminum Panel over Plywood Deck | +N/A/-174.25 | N/A | Yes | Yes |
| FL24423.12 | Tite-Loc Plus (.032" min.) | .032" (min.) x 12" thru 18" Wide Aluminum Panel over Steel Deck | +N/A/-204.25 | N/A | Yes | Yes |
| FL24423.13 | Tite-Loc Plus (24 ga. min.) | 24 ga. (min.) x 12" thru 18" Wide Steel Panel over Steel Deck | +N/A/-196.75 | N/A | Yes | Yes |
| FL24423.14 | Tite-Loc Plus (24 ga. min.) | 24 ga. (min.) x 12" thru 18" Wide Steel Panel over Plywood Deck | +N/A/-204.25 | N/A | Yes | Yes |