FL24397 – 1st Coast Metal Roofing Supply
Florida product approval FL24397-R9 for Roofing Products – Non-structural Metal RF, as listed in ProdApproval’s data as of Sep 29, 2026.
- FL#
- FL24397-R9
- Manufacturer
- 1st Coast Metal Roofing Supply
- Code version
- 2023 Florida Building Code
- Status in our data
- Approved
- Products
- 12
Official record on floridabuilding.org →Use on a spec sheet →
Verify approval status on floridabuilding.org before submitting.
Approved products under FL24397-R9
| Approval # | Model | Description | Design pressure | Wind-borne debris | HVHZ | Outside HVHZ |
|---|---|---|---|---|---|---|
| FL24397.1 | 5V Crimp | 0.032" Aluminum - 5V Crimp 24" Wide Roof Panels Over 1/2" Plywood, Fastened 12" O.C. x 14" O.C. | +N/A/-71.0 | N/A | No | Yes |
| FL24397.2 | 5V Crimp | 26 Ga. Steel - 5V Crimp 24" Wide Roof Panels Over Nominal 7/16" OSB Sheathing, Fastened 12" O.C. x 16" O.C. | +N/A/-52.5 | N/A | No | Yes |
| FL24397.3 | 5V Crimp | 26 Ga. Steel - 5V Crimp 24" Wide Roof Panels Over Nominal 7/16" OSB Sheathing, Fastened (2) 12" O.C. x 24" O.C. | +N/A/-63.5 | N/A | No | Yes |
| FL24397.4 | Armour Loc 0.032" Aluminum | 0.032" Aluminum - 1" Nailstrip x 16" Wide Roof Panels Over 1/2" Plywood, Fastened 4 5/8" O.C. | +N/A/-52.5 | N/A | No | Yes |
| FL24397.5 | Armour Loc 26 Ga. | 26 Ga. Steel - 1" Nailstrip x 16" Wide Roof Panels Over 1/2" Plywood, Fastened 4 3/4" O.C. | +N/A/-86.0 | N/A | No | Yes |
| FL24397.6 | Armour PBR | 26 Ga. Steel - PBR 1 1/8" x 36" Wide Roof Panels Over 1/2" Plywood, Fastened 12" O.C. x 24" O.C. | +N/A/-63.5 | N/A | No | Yes |
| FL24397.7 | Armour Rib 0.032" Aluminum | 0.032" Aluminum - 3/4" Rib x 36" Wide Roof Panels Over 1/2" Plywood, Fastened 9" O.C. x 6" O.C. | +N/A/-78.5 | N/A | No | Yes |
| FL24397.8 | Armour Rib 29 Ga. | 29 Ga. Steel - 3/4" Rib x 36" Wide Roof Panels Over 1/2" Plywood, Fastened 9" O.C. x 24" O.C. | +N/A/-78.5 | N/A | No | Yes |
| FL24397.9 | Armour Rib 29 Ga. | 29 Ga. Steel - 3/4" Rib x 36" Wide Roof Panels Over 1/2" Plywood, Fastened 6"-3"-6" O.C. x 24" O.C. | +N/A/-108.5 | N/A | No | Yes |
| FL24397.10 | Armour Rib 29 Ga. | 29 Ga. Steel - 3/4" Rib x 36" Wide Roof Panels Over 1x4 Wood Battens Over 1/2" Plywood, Fastened 9" O.C. x 24" O.C. | +N/A/-108.5 | N/A | No | Yes |
| FL24397.11 | Armour Rib 29 Ga. | 29 Ga. Steel - 3/4" Rib x 36" Wide Roof Panels Over 1x4 Wood Battens Over 1/2" Plywood, Fastened 6"-3"-6" O.C. x 24" O.C. | +N/A/-183.5 | N/A | No | Yes |
| FL24397.12 | Armour Rib 29 Ga. | 29 Ga. Steel - 3/4" Rib x 36" Wide Roof Panels Over 19/32" OSB Sheathing, Fastened 9" O.C. x 24" O.C. | +N/A/-63.5 | N/A | No | Yes |
Fill a spec sheet with FL24397
On the contractor form, go to the Roofing Products – Non-structural Metal RF row and type 24397 in the Florida Product Approval # box to fill the row. Walton County users can print a PDF that follows the county’s sheet; see the Walton County Product Approval Specification Sheet guide.