FL17631 – UNILUX GmbH
Florida product approval FL17631-R10 for Windows – Fixed, as listed in ProdApproval’s data as of Sep 29, 2026.
- FL#
- FL17631-R10
- Manufacturer
- UNILUX GmbH
- Code version
- 2023 Florida Building Code
- Status in our data
- Approved
- Products
- 3
Official record on floridabuilding.org →Use on a spec sheet →
Verify approval status on floridabuilding.org before submitting.
Approved products under FL17631-R10
| Approval # | Model | Description | Design pressure | Wind-borne debris | HVHZ | Outside HVHZ |
|---|---|---|---|---|---|---|
| FL17631.1 | Series "F" Fixed Window | Series "F" Aluminum Clad Wood Impact Fixed | +55/-55 | Yes | Yes | Yes |
| FL17631.2 | Series "KUDTSF ISOSTAR" | Series "KUDTSF ISOSTAR" UPVC Fixed Window, Non-Impact | +60/-60 | No | No | Yes |
| FL17631.3 | Series "KUF ISOSTAR" | Series "KUF ISOSTAR" UPVC Fixed Window, Non-Impact | +60/-60 | No | No | Yes |
Fill a spec sheet with FL17631
On the contractor form, go to the Windows – Fixed row and type 17631 in the Florida Product Approval # box to fill the row. Walton County users can print a PDF that follows the county’s sheet; see the Walton County Product Approval Specification Sheet guide.