FL17096 – C.H.I. Overhead Doors

Florida product approval FL17096-R8 for Exterior Doors – Sectional, as listed in ProdApproval’s data as of Sep 29, 2026.

FL#
FL17096-R8
Manufacturer
C.H.I. Overhead Doors
Code version
2023 Florida Building Code
Status in our data
Approved
Products
21

Official record on floridabuilding.org →Use on a spec sheet →

Verify approval status on floridabuilding.org before submitting.

Approved products under FL17096-R8

Approval #ModelDescriptionDesign pressureWind-borne debrisHVHZOutside HVHZ
FL17096.117096.01 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 8'-00" through 9'-10" see drawing for applicable pressures.N/ANoNoYes
FL17096.217096.02 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 6'-00" through 11'-00" see drawing for applicable pressures.N/ANoNoYes
FL17096.317096.03 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths up to 9'-00" through 9'-10" see drawing for applicable pressures.N/AYesNoYes
FL17096.417096.04 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 9'-08" through 12'-00" see drawing for applicable pressures.N/ANoNoYes
FL17096.517096.05 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 6'-00" through 11'-04" see drawing for applicable pressures.N/ANoNoYes
FL17096.617096.06 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 10'-00" through 10'-10" see drawing for applicable pressures.N/ANoNoYes
FL17096.717096.07 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 10'-00" through 10'-02" see drawing for applicable pressures.N/AYesNoYes
FL17096.817096.08 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 9'-04" through 10'-02" see drawing for applicable pressures.N/AYesNoYes
FL17096.917096.09 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 10'-00" through 11'-06" see drawing for applicable pressures.N/ANoNoYes
FL17096.1017096.10 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 10'-00" through 14'-00" see drawing for applicable pressures.N/ANoNoYes
FL17096.1117096.11 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 11'-06" through 17'-02" see drawing for applicable pressures.N/ANoNoYes
FL17096.1217096.12 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 11'-00" through 13'-10" see drawing for applicable pressures.N/ANoNoYes
FL17096.1317096.13 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 11'-04" through 13'-04" see drawing for applicable pressures.N/ANoNoYes
FL17096.1417096.14 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 13'-06" through 16'-10" see drawing for applicable pressures.N/ANoNoYes
FL17096.1517096.15 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 11'-04" through 17'-02" see drawing for applicable pressures.N/ANoNoYes
FL17096.1617096.16 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 12'-00" through 16'-06" see drawing for applicable pressures.N/AYesNoYes
FL17096.1717096.17 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 16'-08" through 22'-06" see drawing for applicable pressures.N/ANoNoYes
FL17096.1817096.18 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 16'-04" through 22'-00" see drawing for applicable pressures.N/ANoNoYes
FL17096.1917096.19 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 17'-04" through 24'-00" see drawing for applicable pressures.N/ANoNoYes
FL17096.2017096.20 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 14'-00" through 24'-00" see drawing for applicable pressures.N/ANoNoYes
FL17096.2117096.21 Sandwich Doors, Skyline\PlanksSectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 14'-08" through 20'-00" see drawing for applicable pressures.N/AYesNoYes

Fill a spec sheet with FL17096