FL15722 – Fabral
Florida product approval FL15722-R6 for Roofing Products – Non-structural Metal RF, as listed in ProdApproval’s data as of Sep 29, 2026.
- FL#
- FL15722-R6
- Manufacturer
- Fabral
- Code version
- 2023 Florida Building Code
- Status in our data
- Approved
- Products
- 24
Official record on floridabuilding.org →Use on a spec sheet →
Verify approval status on floridabuilding.org before submitting.
Approved products under FL15722-R6
| Approval # | Model | Description | Design pressure | Wind-borne debris | HVHZ | Outside HVHZ |
|---|---|---|---|---|---|---|
| FL15722.1 | 01 - "5 Rib" | 29 ga. Steel, Exposed Fastener Panel over Wood Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.2 | 02 - "5V Crimp" | 26 ga. Steel, Exposed Fastener Panel over Wood Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.3 | 03 - "Alu-Tuff" | 29 ga. Steel, Exposed Fastener Panel over Wood Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.4 | 04 - "Climaguard", "Horizon S" or "Horizon S100" | 7/8" rib height "Climaguard" or 1.0" rib height "Horizon S" or Horizon S100", 26 ga. Steel, Standing Seam (Snap Lock) Panel over Wood Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.5 | 05 - "Grandrib 3" | 29 ga. Steel, Exposed Fastener Panel over Wood Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.6 | 06 - "Multi-Purpose (MP Panel)" | 29 ga. Steel, Exposed Fastener Panel over Wood Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.7 | 07 - "Power Seam" | 24 ga Steel, Standing Seam (Mech Seam) Panel with 2-pc Clip over Steel Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.8 | 08 - "Power Seam" | 24 ga Steel, Standing Seam (Mech Seam) Panel with Fabral 2-pc Clip over Steel Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.9 | 09 - "Power Seam" or "Power Seam II" | 24 ga Steel, Standing Seam (Mech Seam) Panel with Fabral AMP-Loc High Fixed, AMP-Loc Low Fixed, AMP-Loc High Floating, AMP-Loc Low Floating, PowerSeam Low Floating or PowerSeam High Floating Clip over Wood Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.10 | 10 - "Shelterguard" | 29 ga. Steel, Exposed Fastener Panel over Wood Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.11 | 11 - "Slim Seam 812, Slim Seam 816 or 1-1/2" SSR" | 24 ga Steel, Standing Seam (Snap Lock) Panel with Fabral 1-pc Slim-Seam Clips, over Steel Deck w/Opt Insulation | +N/A/-52.5 | No | No | Yes |
| FL15722.12 | 12 - "Slim Seam 812, Slim Seam 816 or 1-1/2" SSR" | 24 ga Steel, Standing Seam (Snap Lock) Panel with Fabral 1-pc Slim-Seam Clips , over Wood Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.13 | 13 - "Slim Seam 812, Slim Seam 816 or 1-1/2" SSR" | 0.032" Alum. Or 24 ga. Steel, Standing Seam (Snap Lock) Panel with Fabral 1-pc Slim-Seam Clips , over Wood Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.14 | 14 - "Stand'N Seam" | 0.032" Alum. Or 24 ga. Steel, Standing Seam (Mech Seam) Panel with 1-pc Fabral Stand'N Seam Clips, over Steel Deck w/Opt Insulation | +N/A/-52.5 | No | No | Yes |
| FL15722.15 | 15 - "Stand'N Seam" | 0.032" Alum. Or 24 ga. Steel, Standing Seam (Mech Seam) Panel with 1-pc Fabral Stand'N Seam Clips, over Steel Deck w/Gypsum Board | +N/A/-52.5 | No | No | Yes |
| FL15722.16 | 16 - "Stand'N Seam" | 0.032" Alum. Or 24 ga. Steel, Standing Seam (Mech Seam) Panel with 1-pc Fabral Stand'N Seam Clips, over Wood Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.17 | 17 - "Snap-On Seam" | 24 ga. Steel, Batten Seam Panel with 1-pc Clips, over Wood Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.18 | 18 - "Snap-On-Seam or Curved Snap-On-Seam" | 24 ga. Steel, Batten Seam or Curved Batten Seam Panel with 1-pc Clips, over Wood Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.19 | 19 - "Snap-On Seam" | 24 ga. Steel, Batten Seam Panel with 1-pc Clips, over Steel Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.20 | 20 - "Standing Seam T-Rib" | 24 ga. Steel, Standing Seam (Mech Seam) Panel with 1-pc Fabral Standing Seam T-Rib Clips, over Wood Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.21 | 21 - "Standing Seam T-Rib" | 24 ga. Steel, Standing Seam (Mech Seam) Panel with 1-pc Fabral Standing Seam T-Rib Clips, over Steel Deck w/Opt Insulation | +N/A/-52.5 | No | No | Yes |
| FL15722.22 | 22 - "Thin Seam" | 24 ga. Steel, Standing Seam (Snap Lock) Panel with 1-pc Clips, over Wood or OSB Deck w/Opt Insulation | +N/A/-52.5 | No | No | Yes |
| FL15722.23 | 23 - "Thin Seam" | 24 ga. Steel, Standing Seam (Snap Lock) Panel with 1-pc Clips, over Wood Deck | +N/A/-52.5 | No | No | Yes |
| FL15722.24 | 24 - "Thin Seam" | 24 ga. Steel, Standing Seam (Snap Lock) Panel with 1-pc Clips, over Steel Deck w/ Insulation | +N/A/-52.5 | No | No | Yes |
Fill a spec sheet with FL15722
On the contractor form, go to the Roofing Products – Non-structural Metal RF row and type 15722 in the Florida Product Approval # box to fill the row. Walton County users can print a PDF that follows the county’s sheet; see the Walton County Product Approval Specification Sheet guide.