FL14343 – Pella Corporation
Florida product approval FL14343-R7 for Windows – Double Hung, as listed in ProdApproval’s data as of Sep 29, 2026.
- FL#
- FL14343-R7
- Manufacturer
- Pella Corporation
- Code version
- 2023 Florida Building Code
- Status in our data
- Approved
- Products
- 3
Official record on floridabuilding.org →Use on a spec sheet →
Verify approval status on floridabuilding.org before submitting.
Approved products under FL14343-R7
| Approval # | Model | Description | Design pressure | Wind-borne debris | HVHZ | Outside HVHZ |
|---|---|---|---|---|---|---|
| FL14343.1 | Pella Architect Reserve Double Hung, Precision Fit, Clad/Wood, Model 5 (non impact) | Size: 1219x2153mm (48x84.75in) | +40/-40 | No | No | Yes |
| FL14343.2 | Pella Architect Reserve Double Hung, Precision Fit, Clad/Wood, Model 5 (non impact) | Size: 1219x1975mm (48x77.75in) | +45/-45 | No | No | Yes |
| FL14343.3 | Pella Architect Reserve Double Hung, Precision Fit, Clad/Wood, Model 5 (non impact) | Size: 1054x1835mm (41.5x72.25in) | +50/-50 | No | No | Yes |
Fill a spec sheet with FL14343
On the contractor form, go to the Windows – Double Hung row and type 14343 in the Florida Product Approval # box to fill the row. Walton County users can print a PDF that follows the county’s sheet; see the Walton County Product Approval Specification Sheet guide.