FL12316 – Captiveaire Systems
Florida product approval FL12316-R9 for Roofing Products – Other, as listed in ProdApproval’s data as of Sep 29, 2026.
- FL#
- FL12316-R9
- Manufacturer
- Captiveaire Systems
- Code version
- 2020 Florida Building Code
- Status in our data
- Approved
- Products
- 9
Official record on floridabuilding.org →Use on a spec sheet →
Verify approval status on floridabuilding.org before submitting.
Approved products under FL12316-R9
| Approval # | Model | Description | Design pressure | Wind-borne debris | HVHZ | Outside HVHZ |
|---|---|---|---|---|---|---|
| FL12316.1 | Aluminum Roof Top Fans | DU10 through 360, NCA10 through 36, DR10 through 360, DD7 through 36, DDDAR10 through 18, DMUA14, DMUA18, BDU11 through 36, BDCR7 through 36. Models maybe followed by RA/HRA | +150/-150 | Yes | Yes | Yes |
| FL12316.2 | Axial Downblast | HREB24 through 42. Models maybe followed by RA. | +80/-80 | Yes | Yes | Yes |
| FL12316.3 | EGV-IGV Gravity Vents | EGV12x12 through 54x54 IGV12x12 through 54x54 LGVN/LGVX12x12-5 through 24x60-9. Models maybe followed by RA. (Not to be used in ridge area) | +60/-120 | Yes | Yes | Yes |
| FL12316.4 | Gravity Vents | EMUA10 through 18, GV10 through 36, 103CAPASYB08-2R,103CAPASYB10-2R,103CAPASYB12-2R,103CAPASYB14-2R,103CAPASYB16-2R. Models maybe followed by RA. (Not to be used in ridge area) | +100/-100 | Yes | Yes | Yes |
| FL12316.5 | Square Gravity Vent | GVS1113,15,1820,24, 30,36. Models maybe followed by RA. (Not to be used in ridge area) | +100/-100 | Yes | Yes | Yes |
| FL12316.6 | Steel Curb Mounted Utility Set | RE13 through 24BD/DD, RA-RE1300 through 2400BD/DD (Not to be used in ridge area) | +100/-100 | Yes | Yes | Yes |
| FL12316.7 | Steel Rail Mounted Utility Se | USBI11 through 36, RABI11 through 36RM. (Not to be used in ridge area) | +112.5/-112.5 | Yes | Yes | Yes |
| FL12316.8 | Steel Roof Top Fans | HRE13 through 24, BI10 through 36, CB10 through 36, USI100 through 365. RA-VE13 through 24. A Series Steel Supply Fans. Models maybe followed by RA/ARM (Not to be used in ridge area) | +30/-130 | Yes | Yes | Yes |
| FL12316.9 | Steel Supply Fan | CASRTU2 through 4, RARTU2 through 4 (Not to be installed in the ridge area). | +150/-150 | Yes | Yes | Yes |
Fill a spec sheet with FL12316
On the contractor form, go to the Roofing Products – Other row and type 12316 in the Florida Product Approval # box to fill the row. Walton County users can print a PDF that follows the county’s sheet; see the Walton County Product Approval Specification Sheet guide.